Skip to main content

Table 4 Yearly electrical and thermal output of the system and auxiliary energy consumption

From: Performance study and economic analysis of photo-voltaic thermal system under real-life thermal loads in tropical climate

Months

Average solar irradiance

Average thermal output

Average electrical output

Average auxiliary energy

Average hot water consumption

 

(kWh m−2)

(kWh d− 1)

(kWh d− 1)

(kWh d− 1)

(m3)

Sep

4.8

67.5

31.9

0.2

1.39

Oct

4.4

64.1

29.9

1.2

1.76

Nov

3.8

60.1

25.8

3.3

2.80

Dec

3.1

43.4

21.4

0.8

0.79

Jan

4.6

58.8

27.5

1.8

1.79

Feb

3.5

53.2

23.7

3.9

0.90

Mar

4.2

64.4

30.1

0.0

1.09

Apr

4.8

55.1

24.9

0.8

2.26

May

6.5

47.1

25.6

0.0

0.73

Jun

4.7

40.8

26.8

0.0

0.27

Jul

4.1

40.7

23.7

0.9

0.79

Aug

4.5

56.1

29.1

0.0

1.63