Skip to main content

Table 3 Performance evaluation of reclamation processes for various water desalination

From: Performance evaluation of resin wafer electrodeionization for cooling tower blowdown water reclamation

Processa

Capacity (m3 d− 1)

Feed TDS (mg L− 1)

Product water TDS (mg L− 1)

Energy consumption (kWh m−3)

Source

Reference

RO

750

400b

<  5

1.20

Tap water

[40]

RO

6000

1529

<  80

0.83

Ground water

[40]

ED

145,000

5000

500

2.64-5.50

Brackish water

[41]

UF/ED

–

2980

210

0.90

Textile wastewater

[42]

EDR

144

1104

328

0.60

Wastewater tertiary effluent

[24]

EDR

5000

1750

<  500

1.55

Wastewater secondary effluent

[40]

EDI

–

3000

280

1.95

Groundwater

[26]

  1. aRO reverse osmosis, ED electrodialysis, UF ultrafiltration, EDR electrodialysis reversal, EDI electrodeionization
  2. bConverted from conductivity measurement (μS cm−1), 1 μS cm− 1 assumed to be equal to 0.5 mg L− 1 TDS, according to [43]